Anialiner C

Technical Specifications - Anialiner C

Typical values at 50% RH and 23 °C

Property Unit Test method            
Substance g/m2 ISO 536   125 150 170 200  
Moisture % on-line   7,5 7,5 7,5 7,5  
Bursting Strength kPa ISO 2758   310 380 420 470  
SCT cd kN/m ISO 9895   2,05 2,42 2,77 3,23  
                 
Guaranteed values at 50% RH and 23 °C
Property Unit Test method
Substance g/m2 ISO 536 125 150 170 200
Substance tolerance

<---- +/- 3% ----- ---->
Moisture tolerance % on-line <---- +/- 1,5 ----- ---->
Bursting Strength kPa ISO 2758 270 340 380 429
SCT cd kN/m ISO 9895 1,84 2,21 2,50 2,95
Cobb 60 Top Side (max) g/m2 ISO 535 80 80 80 80
Cobb 60 Top Side (min) g/m2 ISO 535 60 60 60 60